Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathmodbus_reader.py
More file actions
208 lines (177 loc) · 8.78 KB
/
modbus_reader.py
File metadata and controls
208 lines (177 loc) · 8.78 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
import minimalmodbus
import time
import math
import os
import sqlite3
from datetime import datetime
from dotenv import load_dotenv
from database import (
DB_FILE,
DATA_RETENTION_DAYS,
get_table_name,
ensure_table_exists,
cleanup_old_data
)
# Laad environment variabelen
load_dotenv()
# Modbus configuratie uit environment met validatie
try:
MODBUS_PORT = os.getenv('MODBUS_PORT', 'COM11')
MODBUS_SLAVE_ID = int(os.getenv('MODBUS_SLAVE_ID', '1'))
MODBUS_BAUDRATE = int(os.getenv('MODBUS_BAUDRATE', '9600'))
MODBUS_BYTESIZE = int(os.getenv('MODBUS_BYTESIZE', '8'))
MODBUS_PARITY = os.getenv('MODBUS_PARITY', 'N')
MODBUS_STOPBITS = int(os.getenv('MODBUS_STOPBITS', '1'))
MODBUS_TIMEOUT = int(os.getenv('MODBUS_TIMEOUT', '1'))
MODBUS_FUNCTION_CODE = int(os.getenv('MODBUS_FUNCTION_CODE', '4'))
MODBUS_REGISTER_TEMP = int(os.getenv('MODBUS_REGISTER_TEMP', '1'))
MODBUS_REGISTER_HUMIDITY = int(os.getenv('MODBUS_REGISTER_HUMIDITY', '2'))
# Valideer configuratie
if MODBUS_SLAVE_ID < 1 or MODBUS_SLAVE_ID > 247:
raise ValueError(f"MODBUS_SLAVE_ID moet tussen 1-247 zijn, kreeg: {MODBUS_SLAVE_ID}")
if MODBUS_BAUDRATE not in [1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200]:
print(f"Waarschuwing: Ongebruikelijke baudrate: {MODBUS_BAUDRATE}")
if MODBUS_PARITY not in ['N', 'E', 'O']:
raise ValueError(f"MODBUS_PARITY moet N, E of O zijn, kreeg: {MODBUS_PARITY}")
if MODBUS_TIMEOUT < 0:
raise ValueError(f"MODBUS_TIMEOUT moet positief zijn, kreeg: {MODBUS_TIMEOUT}")
except ValueError as e:
print(f"FOUT in .env configuratie: {e}")
raise
# Configuratie van Modbus RTU apparaat
# Mapping voor parity settings
PARITY_MAP = {
'N': minimalmodbus.serial.PARITY_NONE,
'E': minimalmodbus.serial.PARITY_EVEN,
'O': minimalmodbus.serial.PARITY_ODD
}
# Global instrument variable - initialized lazily to avoid serial port access during import
instrument = None
def _initialize_instrument():
"""Initialize Modbus instrument - called only when needed, not during module import"""
global instrument
if instrument is None:
instrument = minimalmodbus.Instrument(MODBUS_PORT, MODBUS_SLAVE_ID)
instrument.serial.baudrate = MODBUS_BAUDRATE
instrument.serial.bytesize = MODBUS_BYTESIZE
instrument.serial.parity = PARITY_MAP.get(MODBUS_PARITY, minimalmodbus.serial.PARITY_NONE)
instrument.serial.stopbits = MODBUS_STOPBITS
instrument.serial.timeout = MODBUS_TIMEOUT
return instrument
def read_modbus_data():
"""Thread functie om Modbus data te lezen en op te slaan"""
print(f"→ Modbus thread actief - verbinding maken met {MODBUS_PORT}...")
# Initialize instrument now (not during import)
_initialize_instrument()
last_cleanup = datetime.now()
current_table = get_table_name()
# Optimalisatie: Hergebruik database connectie en batch inserts
conn = sqlite3.connect(DB_FILE, timeout=30)
cursor = conn.cursor()
cursor.execute('PRAGMA journal_mode=WAL')
cursor.execute('PRAGMA synchronous=NORMAL')
print(f"✓ Database connectie OK - schrijven naar tabel: {current_table}")
# Buffer voor batch inserts (30 metingen = 30 seconden)
# Optimalisatie: minder schrijfoperaties = langere levensduur database/storage
measurement_buffer = []
BATCH_SIZE = 30
last_commit_time = time.time()
COMMIT_INTERVAL = 30 # seconds
while True:
try:
# Voer cleanup uit elke 24 uur
if DATA_RETENTION_DAYS > 0 and (datetime.now() - last_cleanup).total_seconds() >= 86400:
cleanup_old_data()
last_cleanup = datetime.now()
register_temp = instrument.read_register(MODBUS_REGISTER_TEMP, 0, MODBUS_FUNCTION_CODE)
register_humidity = instrument.read_register(MODBUS_REGISTER_HUMIDITY, 0, MODBUS_FUNCTION_CODE)
temperature = register_temp / 10
humidity = register_humidity / 10
# Valideer sensor data
if not (-50 <= temperature <= 100):
print(f"Waarschuwing: Ongeldige temperatuur {temperature}°C - meting overgeslagen")
time.sleep(1)
continue
if not (0 <= humidity <= 100):
print(f"Waarschuwing: Ongeldige luchtvochtigheid {humidity}% - meting overgeslagen")
time.sleep(1)
continue
# Bereken dauwpunt
dewpoint = temperature - ((100 - humidity) / 5.0)
# Bereken absolute vochtigheid (g/m³)
# Formule: AH = (6.112 × e^((17.67 × T)/(T+243.5)) × RH × 2.1674) / (273.15+T)
absolute_humidity = (6.112 * math.exp((17.67 * temperature) / (temperature + 243.5)) * humidity * 2.1674) / (273.15 + temperature)
# Bereken Humidex
# Formule: Humidex = T + 0.5555 × (e - 10)
# waarbij e = 6.11 × e^(5417.7530 × (1/273.16 - 1/(273.15+Td)))
# en Td = dauwpunt in Kelvin
dewpoint_kelvin = dewpoint + 273.15
e = 6.11 * math.exp(5417.7530 * ((1/273.16) - (1/dewpoint_kelvin)))
humidex = temperature + 0.5555 * (e - 10)
# Opslaan in buffer (integer timestamp voor performance)
timestamp = datetime.now()
timestamp_int = int(timestamp.timestamp())
measurement_buffer.append((timestamp_int, temperature, humidity, dewpoint, absolute_humidity))
print(f"{timestamp.strftime('%H:%M:%S')} - Temperature: {temperature:.1f}°C, Humidity: {humidity:.1f}%, Dewpoint: {dewpoint:.1f}°C, Absolute Humidity: {absolute_humidity:.1f}g/m³")
# Check of we een nieuwe dag zijn (table switch)
new_table = get_table_name()
if new_table != current_table:
# Flush buffer naar oude tabel
if measurement_buffer:
cursor.execute('BEGIN')
cursor.executemany(
f'INSERT INTO {current_table} (timestamp, temperature, humidity, dewpoint, absolute_humidity) VALUES (?, ?, ?, ?, ?)',
measurement_buffer
)
conn.commit()
print(f"✓ {len(measurement_buffer)} metingen opgeslagen in {current_table} (dag wissel)")
measurement_buffer.clear()
# Maak nieuwe tabel aan en switch
ensure_table_exists(cursor, new_table)
conn.commit()
current_table = new_table
print(f"→ Nieuwe dag: nu schrijven naar {current_table}")
# Batch commit: als buffer vol is OF tijd verstreken
current_time = time.time()
if len(measurement_buffer) >= BATCH_SIZE or (current_time - last_commit_time) >= COMMIT_INTERVAL:
if measurement_buffer:
cursor.execute('BEGIN')
cursor.executemany(
f'INSERT INTO {current_table} (timestamp, temperature, humidity, dewpoint, absolute_humidity) VALUES (?, ?, ?, ?, ?)',
measurement_buffer
)
conn.commit()
print(f"✓ {len(measurement_buffer)} metingen opgeslagen in {current_table} (batch commit)")
measurement_buffer.clear()
last_commit_time = current_time
time.sleep(1)
except Exception as e:
print(f"Modbus fout: {e}")
# Bij fout: probeer buffer alsnog op te slaan
if measurement_buffer:
try:
cursor.executemany(
f'INSERT INTO {current_table} (timestamp, temperature, humidity, dewpoint, absolute_humidity) VALUES (?, ?, ?, ?, ?)',
measurement_buffer
)
conn.commit()
measurement_buffer.clear()
except:
pass
time.sleep(5)
def start_modbus_thread():
"""Start Modbus reader thread als daemon"""
import threading
# Test eerst of minimalmodbus werkt
try:
print(f"→ Start Modbus thread (poort: {MODBUS_PORT}, slave: {MODBUS_SLAVE_ID})")
modbus_thread = threading.Thread(target=read_modbus_data, daemon=True)
modbus_thread.start()
print("✓ Modbus reader thread gestart")
return modbus_thread
except Exception as e:
print(f"✗ FOUT bij starten Modbus thread: {e}")
print(f" Type: {type(e).__name__}")
print(" Zorg dat je de app start met de virtual environment!")
print(" Gebruik: .venv\\Scripts\\python.exe app.py")
raise